The Knee
Volume 14, Issue 1 , Pages 46-50 , January 2007

Biomechanical evaluation of different fixation plates in medial opening upper tibial osteotomy

  • Irfan Esenkaya

      Affiliations

    • Inonu University, School of Medicine, Department of Orthopaedics and Traumatology, 44065, Malatya, Turkey
    • Corresponding Author InformationCorresponding author. Tel.: +90 422 3218555; fax: +90 422 3258283.
  • ,
  • Mesut Misirlioglu

      Affiliations

    • Inonu University, School of Medicine, Department of Orthopaedics and Traumatology, 44065, Malatya, Turkey
  • ,
  • M.Halidun Kelestemur

      Affiliations

    • Firat University, School of Eng., Department of Metallurgical and Materials, Eng., Elazig, Turkey
  • ,
  • Nurzat Elmali

      Affiliations

    • Inonu University, School of Medicine, Department of Orthopaedics and Traumatology, 44065, Malatya, Turkey
  • ,
  • Ersin Fadillioglu

      Affiliations

    • Inonu University, School of Medicine, Department of Physiology, Malatya, Turkey

Received 28 April 2006 ,Revised 11 August 2006 ,Accepted 9 October 2006.

References 

  1. Hanssen A. Osteotomy about the knee: American perspective. In:  Insall JM,  Scott NM editor. Surgery of the knee. Churchill Livingstone; 2001;p. 1447–1464
  2. Hartford JM, Hester P, Watt PM, Hamilton D, Rohmiller M, Pienkowski D. Biomechanical superiority of plate fixation for proximal tibial osteotomy. Clin Orthop. 2003;412:125–130
  3. Klinger HM, Lorenz F, Harer T. Open wedge tibial osteotomy by hemicallotasis for medial compartment osteoarthritis. Arch Orthop Trauma Surg. 2001;121:245–247
  4. Billings A, Scott DF, Camargo MP, Hofmann AA. High tibial osteotomy with a calibrated osteotomy guide, rigid internal fixation, and early motion: long-term follow-up. J Bone Joint Surg Am. 2000;82:70–79
  5. Esenkaya I. Fixation of proximal tibia medial opening wedge osteotomy using plates with wedges. Acta Orthop Traumatol Turc. 2005;39:211–223[Article in Turkish]
  6. Esenkaya I, Elmali N. Proximal tibia medial open-wedge osteotomy using plates with wedges: early results in 58 cases. Knee Surg Sports Traumatol Arthrosc. 2006;14:955–961
  7. Flamme CH, Kohn D, Kirsch L, Hurschler C. Primary stability of different implants used in conjunction with high tibial osteotomy. Arch Orthop Trauma Surg. 19994;119:450–459
  8. Franco V, Cerullo G, Cipolla M, Gianni E, Puddu G. Open wedge high tibial osteotomy. Tech Knee Surg. 2002;1:43–53
  9. Hernigou PH, Medevielle D, Debeyre J, Goutallier D. Proksimal tibial osteotomy for osteoarthritis with varus deformity: a ten to thirteen-year follow-up study. J Bone Joint Surg Am. 1987;69:332–354
  10. Hofmann AA, Wyatt RW, Beck SW. High tibial osteotomy: Use of an osteotomy jig, rigid fixation, and early motion versus conventional surgical technique and cast immobilization. Clin Orthop. 1991;271:212–217
  11. Koshino T, Morii T, Wada J, Saito H, Ozawa N, Noyori K. High tibial osteotomy with fixation by a blade plate for medial compartment osteoarthritis of the knee. Orthop Clin North Am. 1989;20:227–243
  12. Koshino T, Murase T, Saito T. Medial opening-wedge high tibial osteotomy with use of porous hydroxyapatite to treat medial compartment osteoarthritis of the knee. J Bone Joint Surg Am. 2003;85:78–85
  13. Lobenhoffer P, Agneskirchner JD. Improvements in surgical technique of valgus high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc. 2003;11:132–138
  14. Lobenhoffer P, De Simoni C, Staubli AE. Open-wedge high tibial osteotomy with rigid plate fixation. Tech Knee Surg. 2002;1:93–105
  15. Puddu G. High tibial osteotomy (The arthritic knee in the young athlete, SYM 15). In: Abstracts book of 11 th ESSKA 2000 Congress and 4th World Congress on Sports Trauma, Athens-Greece. 2000;p. 446–447
  16. Spahn G, Muckley T, Kahl E, Hofmann GO. Biomechanical investigations of different internal fixations in medial opening-wedge high tibial osteotomy. Clin Biomech (Bristol Avon). 2006;21:272–278
  17. Spahn G, Wittig R. Primary stability of various implants in tibial opening wedge osteotomy: a biomechanical study. J Orthop Sci. 2002;7:683–687
  18. Agneskirchner JD, Freling D, Hurschler C, Lobenhoffer P. Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc. 2006;14:291–300
  19. Stoffel K, Stachowiak G, Kuster M. Open wedge high tibial osteotomy: biomechanical investigation of the modified arthrex osteotomy plate (Puddu Plate) and the Tomofix Plate. Clin Biomech. 2004;19:944–950
  20. Stuart MJ, Beachy AM, Grabowski JJ, An KN, Kaufman KR. Biomechanical evaluation of a proximal tibial opening wedge osteotomy plate. Am J Knee Surg. 1999;12:148–153
  21. Zhim F, Laflamme GY, Viens H, Laflamme GH, Yahia L. Biomechanical stability of a retrotubercle opening wedge high tibial osteotomy. J Knee Surg. 2006;19:28–32
  22. Esenkaya I. A new distractor with angle-scale for proximal tibia medial opening wedge osteotomy. Knee Surg Sports Traumatol Arthrosc. 2006;14:443–446
  23. Kuster MS, Wood GA, Stachowiak GW, Gachter A. Joint load consideration in total knee replacement. J Bone Joint Surg Br. 1997;79:109–113
  24. Morrison JB. The mechanics of the knee joint in relation to normal walking. J Biomech. 1970;3:51–61

PII: S0968-0160(06)00166-9

doi: 10.1016/j.knee.2006.10.003

The Knee
Volume 14, Issue 1 , Pages 46-50 , January 2007