The Knee
Volume 17, Issue 2 , Pages 108-113, March 2010

Synthetic grafts for anterior cruciate ligament rupture: 19-year outcome study

  • Alberto Ventura

      Affiliations

    • I Divisione, Istituto Ortopedico G. Pini, Milano, Italy
    • Corresponding Author InformationCorresponding author. Tel.: +39 0239322793; fax: +39 0239322793.
  • ,
  • Clara Terzaghi

      Affiliations

    • I Scuola di Specializzazione in Ortopedia e Traumatologia, Università degli Studi di Milano, Milano, Italy
  • ,
  • Claudio Legnani

      Affiliations

    • I Scuola di Specializzazione in Ortopedia e Traumatologia, Università degli Studi di Milano, Milano, Italy
  • ,
  • Enrico Borgo

      Affiliations

    • I Divisione, Istituto Ortopedico G. Pini, Milano, Italy
  • ,
  • Walter Albisetti

      Affiliations

    • I Scuola di Specializzazione in Ortopedia e Traumatologia, Università degli Studi di Milano, Milano, Italy

Received 2 December 2008; received in revised form 22 July 2009; accepted 23 July 2009. published online 01 September 2009.

Abstract 

Artificial ligaments for ACL replacement have been widely used in the 1980s and early 1990s in orthopaedic surgery. Synthetic devices have been utilized either as a prosthetic material or as an augmentation for a biological ACL graft substitute. The initial enthusiasm surrounding the introduction of synthetic graft materials stemmed from their lack of donor morbidity, their abundant supply and significant strength of these devices. The disadvantages in long-term follow-up were found to be cross-infections, immunological responses, tunnels osteolysis, femural and tibial fractures, foreign-body synovitis and knee osteoarthritis.

A total of 126 patients were treated with artificial ACL substitution with polyethylene terephthalate (PET) synthetic ligaments in our Institute between 1986 and 1990. Of the original group, 51 sportsmen aged 15 to 40 were followed-up at a mean of 19years (range 17.5 to 20.6years) after surgery. Assessment was made with KOOS and IKDC score, Tegner activity scale, clinical examination, KT-1000 arthrometer, and X-ray evaluation.

Of the 51 patients followed-up, 27.5% were found to have ruptured their PET ligaments and 100% presented degenerative osteoarthritis at the X-ray evaluation according to Ahlbäck radiological classification of arthritis. The objective evaluation showed functional impairment in 29.4% with an average reduction of 3 points in the Tegner activity scale.

The osteoarthritis observed in all patients prompted us to avoid the diffusion of this surgical technique. Although in theory well-conceived, studies have yet to substantiate the function of these augmentation devices or to show clinical better results than those achieved with isolated autograft or allograft ACL substitutes.

Keywords: ACL, Synthetic ligament, Osteoarthritis

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0968-0160(09)00130-6

doi:10.1016/j.knee.2009.07.013

The Knee
Volume 17, Issue 2 , Pages 108-113, March 2010