The Knee
Volume 17, Issue 3 , Pages 245-248, June 2010

Effect of tendon tensioning: An in vitro study in porcine extensor tendons

  • David Figueroa

      Affiliations

    • Orthopaedic Surgery Department, Clínica Alemana and Universidad del Desarrollo, Santiago, Chile
    • Corresponding Author InformationCorresponding author. Apoquindo 3990, Of. 401, Las Condes, Santiago, Chile. Tel.: +56 207 0402; fax: +56 207 0407.
  • ,
  • Rafael Calvo

      Affiliations

    • Knee Surgery Unit, Orthopaedic Surgery Department, Clínica Alemana and Universidad del Desarrollo, Santiago, Chile
  • ,
  • Alex Vaisman

      Affiliations

    • Knee Surgery Unit, Orthopaedic Surgery Department, Clínica Alemana and Universidad del Desarrollo, Santiago, Chile
  • ,
  • Patricio Meleán

      Affiliations

    • Knee Surgery Unit, Orthopaedic Surgery Department, Clínica Alemana and Universidad del Desarrollo, Santiago, Chile
  • ,
  • Francisco Figueroa

      Affiliations

    • Orthopaedic Surgery Department, Clínica Alemana and Universidad del Desarrollo, Santiago, Chile

Received 6 March 2009; received in revised form 10 August 2009; accepted 10 August 2009. published online 10 September 2009.

Abstract 

Graft tensioning is a controversial issue in anterior cruciate ligament reconstruction (ACLR) that has not achieved consensus between peers. The purpose of this study is to determine if after tensioning tendon length and resistance to maximal load changes. We performed an in vitro study with 50 porcine extensors tendons. The first group (P=25) was tensioned with 80 N (19.97 lb) for 10 min, using an ACL graft preparation board. The second group (C=25) was used as control and was not tensioned. The average initial (groups P and C) and post tensioning tendon length (group C) were measured; the average initial and post tensioning tendon diameter were measured as well. All samples were fixated in a tube–clamp system connected to a tension sensor. The samples were stressed with continuous and progressive tension until ultimate failure at maximum load (UFML) occurs. The initial mean length was: P before tensioning=13.4 mm±1.4 mm (range 10.5–16.5); P after tensioning=13.8 mm±1.4 mm (range 11.5–16.5); C=13 mm±1.35 mm (p=0.005). The mean diameter was: P=5.6 mm (4.5–6); C=5.5 mm (range 4.5–6) (p>0.05). The UFML was: P=189.7 N (114–336); C=229.9 N (143–365) (p=0.029). Tendon tensioning with 80 N for 10 min produced 3% average elongation. These could be beneficial in ACLR since tendon tensioning decreases elongation of the graft after fixation. Regardless, tendon tensioning is not innocuous since it diminishes their resistance when continuously stressed until complete failure occurs.

Keywords: Tensioning, ACL, Experimental study, Graft elongation, Maximum load changes

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0968-0160(09)00137-9

doi:10.1016/j.knee.2009.08.005

The Knee
Volume 17, Issue 3 , Pages 245-248, June 2010